Aerobic Sludge Sewage Treatment Pilot
Categories: Lab EquipmentAerobic Sludge Sewage Treatment Pilot Industrial pollution, by its variety and significant increase in volume, in temperature, and in toxicity, prevents all" auto-cleaning" of the different rivers; th...

Product
Description
Aerobic Sludge Sewage Treatment Pilot
Industrial pollution, by its variety and significant increase in volume, in temperature, and in toxicity, prevents all" auto-cleaning" of the different rivers; these waters are lifeless: the bacteria cannot develop themselves and the purification cannot in most of cases achieve itself, because the biologic and chemical balances are broken. Industrial scientific research turned toward the development of new specific biological products, of which the technique of bio-fixing (a high technology process where the bacteria are fixed under an active form in microscopic porous support sites). This pilot microbiologically eliminates carbon, nitrogen, and phosphorous pollution. It functions when the sewage is put in contact with a bacterial sludge in the presence of oxygen, followed by a phase of separation of the sludge.
Teaching objectives
To obtain the maximum purification output by varying :- Volumic and specific load
- Sludge age
- Bioflocculate quality
- Ventilation
Analysis:
- Dissolved 0²
- pH
- Temperature
Technical specifications
- White polyethylene supply tank with lid and casters.
- Stainless steel circulator to maintain and stir the substrate.
- Plexiglass oxidation tank with lid.
- Rushton variable speed stirrer, with display.
- Air injection rod.
- Ceramic diffuser.
- Air pump.
- One gas rotameter, one liquid rotameter.
- Two peristaltic pumps recycle the sludge and the substrate at variable flow.
- Plexiglass sedimentation tank.
- Collection tank for the purified water.
- Continuous dissolved oxygen measuring probe with transmitter-regulator. The air pump is regulated at this oxygen measurement.
- Continuous pH measuring probe with its transmitter with two alarms.
- Temperature probe situated at the bottom of the oxidization tank with display on the switchboard.
- An immersed heater to maintain the temperature for the micro-organisms.
- A control cabinet regrouping the start/stop controls for the three pumps, circulator, and stirrer. Two sequencing units are supplied to plan the working cycles of these elements. The cabinet includes the oxygen, pH, and temperature probe transmitters.
- The unit is made from PVC and Plexiglass on a stainless steel frame with aluminum nuts.
Dimensions
- 1 700 x 700 x 2 000 mm.
Essential requirements
- Power supply: 220 V / single phase / 50 Hz
- Consumption: less than 1000 W
Recommended products :
- Activated sludge or enzymes.
- Characterized substrate.
quick overview :
Aerobic Sludge Sewage Treatment Pilot
Industrial pollution, by its variety and significant increase in volume, in temperature, and in toxicity, prevents all" auto-cleaning" of the different rivers; these waters are lifeless: the bacteria cannot develop themselves and the purification cannot in most of cases achieve itself, because the biologic and chemical balances are broken. Industrial scientific research turned toward the development of new specific biological products, of which the technique of bio-fixing (a high technology process where the bacteria are fixed under an active form in microscopic porous support sites). This pilot microbiologically eliminates carbon, nitrogen, and phosphorous pollution. It functions when the sewage is put in contact with a bacterial sludge in the presence of oxygen, followed by a phase of separation of the sludge.
Teaching objectives
To obtain the maximum purification output by varying :- Volumic and specific load
- Sludge age
- Bioflocculate quality
- Ventilation
Analysis:
- Dissolved 0²
- pH
- Temperature
Technical specifications
- White polyethylene supply tank with lid and casters.
- Stainless steel circulator to maintain and stir the substrate.
- Plexiglass oxidation tank with lid.
- Rushton variable speed stirrer, with display.
- Air injection rod.
- Ceramic diffuser.
- Air pump.
- One gas rotameter, one liquid rotameter.
- Two peristaltic pumps recycle the sludge and the substrate at variable flow.
- Plexiglass sedimentation tank.
- Collection tank for the purified water.
- Continuous dissolved oxygen measuring probe with transmitter-regulator. The air pump is regulated at this oxygen measurement.
- Continuous pH measuring probe with its transmitter with two alarms.
- Temperature probe situated at the bottom of the oxidization tank with display on the switchboard.
- An immersed heater to maintain the temperature for the micro-organisms.
- A control cabinet regrouping the start/stop controls for the three pumps, circulator, and stirrer. Two sequencing units are supplied to plan the working cycles of these elements. The cabinet includes the oxygen, pH, and temperature probe transmitters.
- The unit is made from PVC and Plexiglass on a stainless steel frame with aluminum nuts.
Dimensions
- 1 700 x 700 x 2 000 mm.
Essential requirements
- Power supply: 220 V / single phase / 50 Hz
- Consumption: less than 1000 W
Recommended products :
- Activated sludge or enzymes.
- Characterized substrate.

Product
Reviews
add Review
reviews
No Review Yet.
Product
Reviews
add Review
reviews
No Review Yet.