PLC Trainer
Categories: Educational TrainersPLC Trainer Technical Specifications of PLC Trainer : Control Method : Cyclic execution of stored program, Time-driven operation, Interrupt task operation I/O Control Method : Scan synchronize...
Product
Description
PLC Trainer
Technical Specifications of PLC Trainer : Control Method : Cyclic execution of stored program, Time-driven operation, Interrupt task operation I/O Control Method : Scan synchronized batch processing method (Refresh Method) Program Language : LD (Ladder Diagram), IL (Instruction list), SFC (Sequential Function chart) Number of Instructions : LD(20 EA), IL (13 EA), SFC (194 EA) Processing speed : 0.2/Step Program Memory Capacity : 128 Kbyte Maximum I/O Points : 512 points (With 16 pt modules), 1024 points (With 32 pt modules) 2048 points (With 64 pt modules)Digital Input :
Input Point : 16 Points ( 2 EA ) Rated input Voltage : DC 12/24 V Common Method : 8 Points / 1 Com Insulated Method : Photo Coupler InsulationDigital Output :
Output Point : 16 Points ( 2 EA ) Rated Load Voltage : DC 12V, AC 220V Rated Load Current : Max. 2A Common Method : 8 Points / 1 Com Insulation method : Relay Insulation Power Module : AC 50Hz / 60Hz, ; DC 5V/4A, 24V/0.7A Vibration Proof Module : Vibration proof for non use slot Base : 8 slot ( maximum number of module attach 8 EA )Trainer Power Supply :
Power : AC, 50Hz / 60Hz Meter : 1 EA Main power ( Built in current protection device ) : 1 unit PLC power ( built in Current protection device ) : 1 unit DC output power (DC 24V) : 1 Unit Output Terminal : 4 EASensor Input and Motor Device :
DC Motor (DC 24V) : 1 Unit Coupling : circular type ( Hole 4 EA / Magnetic 1 EA ) Photo sensor ( Detection Distance : 200 mm ) : 1 EA Proximity Sensor ( Detection Distance : 8 mm ) : 1 EA Power for sensor : DC 12V ~ 24VInput Signal Device :
Non lock type push button : 7 EA Lock type push button : 1 EA Digital switch (BCD, 2 digits) : 1 UnitOutput Signal Indication :
Output Lamp (DC 24V) : 7 EA Buzzer (DC 24V) : 1 EA Digital switch (BCD, 2 digits) : 1 UnitDigital I/O Terminals :
Input : 32 Points ( 16 points / 1 COM Total 4 EA ) Output : 32 Points ( 16 Points / 1 COM Total 4 EA ) Training Contents : Basic Commands, LOAD and LOAD NOT Basic Commands, AND and AND NOT Basic Commands, OR and OR NOT Basic Command, Coil Commands, SET and RST Self holding circuit Transition – Sensing Coils Function Block Command, TON Function Block Command, TOF Function Commands, CTU & CTD Function Commands, MCS and MCS CLR Quiz Circuit Electric Motor and Pulse sensor 1 Electric Motor and Pulse sensor 2quick overview :
PLC Trainer
Technical Specifications of PLC Trainer : Control Method : Cyclic execution of stored program, Time-driven operation, Interrupt task operation I/O Control Method : Scan synchronized batch processing method (Refresh Method) Program Language : LD (Ladder Diagram), IL (Instruction list), SFC (Sequential Function chart) Number of Instructions : LD(20 EA), IL (13 EA), SFC (194 EA) Processing speed : 0.2/Step Program Memory Capacity : 128 Kbyte Maximum I/O Points : 512 points (With 16 pt modules), 1024 points (With 32 pt modules) 2048 points (With 64 pt modules)Digital Input :
Input Point : 16 Points ( 2 EA ) Rated input Voltage : DC 12/24 V Common Method : 8 Points / 1 Com Insulated Method : Photo Coupler InsulationDigital Output :
Output Point : 16 Points ( 2 EA ) Rated Load Voltage : DC 12V, AC 220V Rated Load Current : Max. 2A Common Method : 8 Points / 1 Com Insulation method : Relay Insulation Power Module : AC 50Hz / 60Hz, ; DC 5V/4A, 24V/0.7A Vibration Proof Module : Vibration proof for non use slot Base : 8 slot ( maximum number of module attach 8 EA )Trainer Power Supply :
Power : AC, 50Hz / 60Hz Meter : 1 EA Main power ( Built in current protection device ) : 1 unit PLC power ( built in Current protection device ) : 1 unit DC output power (DC 24V) : 1 Unit Output Terminal : 4 EASensor Input and Motor Device :
DC Motor (DC 24V) : 1 Unit Coupling : circular type ( Hole 4 EA / Magnetic 1 EA ) Photo sensor ( Detection Distance : 200 mm ) : 1 EA Proximity Sensor ( Detection Distance : 8 mm ) : 1 EA Power for sensor : DC 12V ~ 24VInput Signal Device :
Non lock type push button : 7 EA Lock type push button : 1 EA Digital switch (BCD, 2 digits) : 1 UnitOutput Signal Indication :
Output Lamp (DC 24V) : 7 EA Buzzer (DC 24V) : 1 EA Digital switch (BCD, 2 digits) : 1 UnitDigital I/O Terminals :
Input : 32 Points ( 16 points / 1 COM Total 4 EA ) Output : 32 Points ( 16 Points / 1 COM Total 4 EA ) Training Contents : Basic Commands, LOAD and LOAD NOT Basic Commands, AND and AND NOT Basic Commands, OR and OR NOT Basic Command, Coil Commands, SET and RST Self holding circuit Transition – Sensing Coils Function Block Command, TON Function Block Command, TOF Function Commands, CTU & CTD Function Commands, MCS and MCS CLR Quiz Circuit Electric Motor and Pulse sensor 1 Electric Motor and Pulse sensor 2Product