Selective Ion Analyzer

Selective Ion Analyzer

Categories: Mining Engineering Lab

Specification:- Measuring Ranges: pH: -2.000 to +19.999, -2.00 to +19.99 mV: -999.9 to +999.9, -1999 to +1999 Temp: -23 to 221 °F (-5.0 to 105.0 °C) ISE: 0.000 to 9.999 mg/l, 0.00 to 99.9 mg/l,...


title icon
Product

Description

Specification:-

  • Measuring Ranges:
pH: -2.000 to +19.999, -2.00 to +19.99 mV: -999.9 to +999.9, -1999 to +1999 Temp: -23 to 221 °F (-5.0 to 105.0 °C) ISE: 0.000 to 9.999 mg/l, 0.00 to 99.9 mg/l, 0.0 to 999.9 mg/l, or 0 to 1999 mg/l
  • Measuring Resolution: pH: 0.001, 0.01 mV: 0.1, 1 Temp: 0.2°F (0.1°C)
ISE: 0.001 mg/l, 0.01 mg/l, 0.1 mg/l, 1 mg/l
  • Precision:
pH (+ pH units from the calibration point): +0.003 from 59 to 95 °F (15 to 35 °C), +0.01 mV: +0.2 from 59 to 95 °F (15 to 35 °C) Temp: +0.1 (NTC 30); +0.5 from 32 to 59 °F (0 to 15 °C), +0.1 from 59 to 95 °F (15 to 35 °C), +0.2 from 95 to 131 °F (35 to 55 °C) (PT 1000)
  • pH correction function: Manual from -4 to 266 °F (-20 to 130 °C)
  • Usable ISE electrodes: Combination and single electrodes with connector according to DIN 19262 ISE calibration procedure: Two point calibration or three point calibration with standards suiting the sample ISE slope ranges: ± 25 to 35 mV and ± 50 to 70 Mv
  • Serial Interface
Baud Rate: Adjustable: 1200, 2400, 4800, 9600 Baud Type: RS232, data output Data Bits: 8 Stop Bits: 2 Parity: None Handshake: RTS/CTS + Xon/Xoff Cable Length: Max. 15m
  • Ambient Conditions:
Storage: -13 to +149 °F (-25 to +65 °C) Operation: 14 to 131 °F (-10 to +55 °C) Climatic Class: 2
  • Power:
Batteries: 4 x 1.5 V alkali-manganese batteries, type AA Operational Life: approx. 3000 operating hours
  • Mains:
The following applies to all plug-in power supplies: Connection max. overvoltage category II Input: 100 to 240 V ~ / 50 to 60 Hz / 400 mA Output: 9 V = / 1.5 A
  • Weight: 0.7 lbs (0.3 kg)
Size: 6.8x3.1x1.5 in (172x80x37 mm)


title icon
Product

Reviews

add Review
reviews

    No Review Yet.

quick overview :

Specification:-

  • Measuring Ranges:
pH: -2.000 to +19.999, -2.00 to +19.99 mV: -999.9 to +999.9, -1999 to +1999 Temp: -23 to 221 °F (-5.0 to 105.0 °C) ISE: 0.000 to 9.999 mg/l, 0.00 to 99.9 mg/l, 0.0 to 999.9 mg/l, or 0 to 1999 mg/l
  • Measuring Resolution: pH: 0.001, 0.01 mV: 0.1, 1 Temp: 0.2°F (0.1°C)
ISE: 0.001 mg/l, 0.01 mg/l, 0.1 mg/l, 1 mg/l
  • Precision:
pH (+ pH units from the calibration point): +0.003 from 59 to 95 °F (15 to 35 °C), +0.01 mV: +0.2 from 59 to 95 °F (15 to 35 °C) Temp: +0.1 (NTC 30); +0.5 from 32 to 59 °F (0 to 15 °C), +0.1 from 59 to 95 °F (15 to 35 °C), +0.2 from 95 to 131 °F (35 to 55 °C) (PT 1000)
  • pH correction function: Manual from -4 to 266 °F (-20 to 130 °C)
  • Usable ISE electrodes: Combination and single electrodes with connector according to DIN 19262 ISE calibration procedure: Two point calibration or three point calibration with standards suiting the sample ISE slope ranges: ± 25 to 35 mV and ± 50 to 70 Mv
  • Serial Interface
Baud Rate: Adjustable: 1200, 2400, 4800, 9600 Baud Type: RS232, data output Data Bits: 8 Stop Bits: 2 Parity: None Handshake: RTS/CTS + Xon/Xoff Cable Length: Max. 15m
  • Ambient Conditions:
Storage: -13 to +149 °F (-25 to +65 °C) Operation: 14 to 131 °F (-10 to +55 °C) Climatic Class: 2
  • Power:
Batteries: 4 x 1.5 V alkali-manganese batteries, type AA Operational Life: approx. 3000 operating hours
  • Mains:
The following applies to all plug-in power supplies: Connection max. overvoltage category II Input: 100 to 240 V ~ / 50 to 60 Hz / 400 mA Output: 9 V = / 1.5 A
  • Weight: 0.7 lbs (0.3 kg)
Size: 6.8x3.1x1.5 in (172x80x37 mm)

title icon
Product

Reviews

add Review
reviews

    No Review Yet.